Hold-Open Systems

  • Individually configurable
  • Ensures accessibility
  • Effective protection
A hold-open system generally consists of a hold-open device, such as a holding magnet, one or more smoke detectors, a release mechanism, and the power supply. As long as no smoke is detected, the hold-open device keeps the door open. As soon as the smoke detectors detect smoke particles or a manual release button is pressed, the magnet is de-energized. The door then closes automatically via the existing door closer, restoring the protective function of the fire or smoke barrier closure.

Hold-open systems are frequently used in hallways, stairwells, hospitals, care facilities, schools, or administrative buildings. They allow for convenient pedestrian and material traffic without compromising the protective effect of the fire safety barriers.

Hold-open systems serve to keep fire and smoke doors open during normal operation and close them automatically in the event of a fire. This prevents fire and especially smoke from spreading uncontrollably into other areas of the building or fire compartments.

Find the optimal solution for your building type with us!

System types: Hold-open systems (FSA) for single- or double-leaf fire doors, as well as for fire gates
Components: Control unit of the hold-open system, holding magnet, smoke detector, release button, door closer
Standards & Norms: DIN 14677, DIN EN 1154/1155, VdS-compliant

Residential Buildings
Public Institutions
Industry and Commerce

We are happy to advise you and work with you to find the right hold-open system for your building and purpose.

We professionally install all components, regularly inspect and maintain them, and repair them as needed. You will also receive detailed instructions and training on how to use the system.

Hold-Open Systems: Manufacturers & Supplier(s)

Discover more ...

An electronic keypad mounted on the wall with a display, ten round buttons on the sides, and a numeric keypad below. The bottom cover is open. The device is labeled "Jablotron" and appears to be part of a modern fire alarm system or warning system, as commonly used in company buildings in Upper Palatinate. Contact us for a non-binding offer tailored to your security needs. – Brandschutztechnik Eller

Alarm Systems

Alarm systems detect dangers early and help protect people and assets. They are used in industry and commerce, public buildings, and private homes.

Sensors and detectors detect potential hazards (e.g., smoke development, gas leaks, movement, glass breakage, temperature changes), which are then processed in a central unit, triggering an alarm visually, acoustically, or by transmitting a signal directly to security services or control centers. Additionally, you can integrate further functions, such as video surveillance.
Two red fire extinguishers of different sizes with black hoses and nozzles stand upright against a white background. The labels on both are in German. – Brandschutztechnik Eller

Carbon Dioxide Fire Extinguishers

Carbon dioxide fire extinguishers are primarily suitable for Class B fires – i.e., flammable liquids and substances that become liquid when heated. Typical areas of use include hazardous materials storage facilities, laboratories, and the aviation and maritime sectors.

The extinguishing agent is carbon dioxide (CO₂), stored under high pressure and directed straight at the seat of the fire. The extinguishing effect is mainly achieved by displacing oxygen – the fire is smothered. The key advantage: CO₂ evaporates without leaving any residue, so there is no damage caused by powder or foam residue – or water – during fire suppression.

Carbon dioxide extinguishers are also well suited for fires in electrical installations, such as data centers and server stations. If a minimum distance of 1 m is maintained, fires in installations up to 1,000 volts can be extinguished with them (see fire-fighting guidelines DIN VDE 0132).
Red Gloria fire extinguisher with instructions in German and English on the label. – Brandschutztechnik Eller

Dry Powder Fire Extinguishers

Dry powder fire extinguishers suit fires in Classes A, B, and C, solid, liquid, and gaseous substances. Their versatility makes them ideal for locations where different combustible materials are stored together, such as industrial facilities, tank farms, multi-story and underground car parks, parking garages, production halls, warehouses, or heating systems.

For larger fire scenarios, wheeled extinguishers are suitable: Large wheels (30 cm) and a tip-resistant design make them easy to transport to the scene, even across level changes. The extinguishers feature a long, high-pressure hose and a swiveling, parkable discharge gun, allowing one person to operate them flexibly. All wheeled extinguishers in our range are tested to DIN EN 1866.

Portable dry powder fire extinguishers are suitable for smaller fires in commercial and private settings. However, as the powder extinguishing agent leaves residue, we do not recommend using it indoors; it is primarily intended for outdoor use.
Hold-Open Systems

Enquiry Assistant

How does it work? Simply select products and specify the desired quantity. Then enter your contact details and submit straight away. We will review your enquiry and get back to you promptly.

Product group: Hold-Open Systems
Residential Buildings
Public Institutions
Industry and Commerce

Your contact details: